Publicación:
Smoothing filters in synthetic cerebral magnetic resonance images: A comparative study

dc.contributor.authorGelvez Almeida, Elkin
dc.contributor.authorVera, Miguel Ángel
dc.contributor.authorHuérfano Maldonado, Yoleidy Katherine
dc.contributor.authorValbuena Prada, Óscar
dc.contributor.authorSalazar Echeverria, Williams Justo José
dc.contributor.authorVera Contreras, María Isabel
dc.contributor.authorBorrero Rodríguez, Maryuri Astrid
dc.contributor.authorBarrera Cortes, Doris Yaneth
dc.contributor.authorHernández Morantes, Carlos
dc.contributor.authorMolina Mujica, Ángel Valentín
dc.contributor.authorMartínez, Luis Javier
dc.contributor.authorSáenz Peña, Frank Hernando
dc.contributor.author‪Vivas García, Marisela
dc.contributor.authorContreras Velásquez, Julio César
dc.contributor.authorRestrepo Morales, Jorge Aníbal
dc.contributor.authorVanegas López, Juan Gabriel
dc.contributor.authorSalazar Torres, Juan Pablo
dc.contributor.authorContreras Santander, Yudith Liliana
dc.date.accessioned2023-05-01T21:35:28Z
dc.date.available2023-05-01T21:35:28Z
dc.date.issued2018
dc.description.abstractThis paper presents the evaluation of two computational techniques for smoothing noise that might be present in synthetic images or numerical phantoms of magnetic resonance (MRI). The images that will serve as the databases (DB) during the course of this evaluation are available freely on the Internet and are reported in specialized literature as synthetic images called BrainWeb. The images that belong to this DB were contaminated with Rician noise, this being the most frequent type of noise in real MRI images. Also, the techniques that are usually considered to minimize the impact of Rician noise on the quality of BrainWeb images are matched with the Gaussian filter (GF) and an anisotropic diffusion filter, based on the gradient of the image (GADF). Each of these filters has 2 parameters that control their operation and, therefore, undergo a rigorous tuning process to identify the optimal values that guarantee the best performance of both the GF and the GADF. The peak of the signal-to-noise ratio (PSNR) and the computation time are considered as key elements to analyze the behavior of each of the filtering techniques applied. The results indicate that: a) both filters generate PSNR values comparable to each other. b) The GF requires a significantly shorter computation time to soften the Rician noise present in the considered DB. Keywords: Synthetic Cerebral images, Magnetic resonance, Rician noise, Gaussian filter, Anisotropic diffusion filter, PSNR.
dc.description.abstractEste artículo presenta la evaluación de dos técnicas computacionales para el suavizado de ruido, que puede estar presente en imágenes sintéticas o phantoms numéricos de resonancia magnética (MRI). Las imágenes que servirán como bases de datos (DB) para el desarrollo de la mencionada evaluación están disponibles, de manera libre, en la Internet y se reportan, en la literatura especializada, como imágenes sintéticas denominadas BrainWeb. Las imágenes pertenecientes a esta DB fueron contaminadas con ruido Riciano debido a que este es el tipo de ruido más frecuente en imágenes de MRI reales. Por otra parte, las técnicas consideradas para minimizar el impacto de este ruido, en la calidad de las imágenes de la BrainWeb, se hacen coincidir con el filtro Gausiano (GF) y un filtro de difusión anisotrópica, basado en el gradiente de la imagen (GADF). Cada uno de estos filtros posee 2 parámetros que controlan su funcionamiento y, por ende, deben someterse a un proceso de entonación riguroso para identificar los valores óptimos que garanticen el mejor desempeño tanto del GF como del GADF. El pico de la relación señal a ruido (PSNR) y el tiempo de cómputo son considerados como elementos clave para analizar el comportamiento de cada una de las técnicas de filtrado aplicadas. Los resultados indican que: a) Ambos filtros generan valores de PSNR comparables entre sí. b) El GF requiere de un tiempo de cómputo, significativamente, menor para suavizar el ruido Riciano presente en la DB considerada. Palabras clave: Imágenes sintéticas cerebrales, Resonancia magnética, Ruido Riciano, Filtro Gausiano, Filtro de difusión anisotrópica, PSNR.
dc.format.extent4 páginasspa
dc.format.mimetypeapplication/pdfspa
dc.identifier.eissn2610-7996spa
dc.identifier.issn1856-4550spa
dc.identifier.urihttps://dspace.tdea.edu.co/handle/tdea/2845
dc.language.isoengspa
dc.publisherCooperativa Servicios y Suministros 212518spa
dc.publisher.placeVenezuelaspa
dc.relation.citationendpage338spa
dc.relation.citationissue4spa
dc.relation.citationstartpage335spa
dc.relation.citationvolume13spa
dc.relation.ispartofjournalRevista Latinoamericana de Hipertensiónspa
dc.relation.referencesGudbjartsson H. y Patz S.The rician distribution of noisy MRI data, Magn. Reson. Med. 34 (1) (1995) 910914.spa
dc.relation.referencesMacovski A. (1996). Noise in MRI, Magn. Reson. Med. 36 (1) 494497spa
dc.relation.referencesCocosco C., Kollokian V., Kwan R. y Evans A. (1997). BrainWeb: Online Interface to a 3D MRI Simulated Brain Database. NeuroImage, 5(4), part 2/4, S425, 1997. Proceedings of 3-rd International Conference on Functional Mapping of the Human Brain, Copenhagen.spa
dc.relation.referencesKwan R., Evans A. y Pike G. (1999). MRI simulation-based evaluation of image processing and classification methods. IEEE Transactions on Medical Imaging. 18(11):1085-97.spa
dc.relation.referencesCollins D., Zijdenbos A., Kollokian V., Sled J. y Kabani N., Holmes C., Evans A. (1998). Design and Construction of a Realistic Digital Brain Phantom. IEEE Transactions on Medical Imaging, 17(3):463-468.spa
dc.relation.referencesKwan R., Evans A. y Pike G. (1996). An Extensible MRI Simulator for Post-Processing-Evaluation-Visualization in Biomedical Computing (VBC’96). Lecture Notes in Computer Science, 1131:135-140.Springer-Verlag,spa
dc.relation.referencesCoupé P., Yger P., Prima S., Hellier P., Kervrann C. y Barillot C. (2008). An optimized blockwise nonlocal means denoising filter for 3-D magnetic resonance images, IEEE Trans. Med. Imag. 27(4):425–441.spa
dc.relation.referencesPerona P. y Malik J. (1990). Scalespace and edge detection using anisotropic diffusion, IEEE Trans. on Patt. Analysis and Machine Intelligence 12(7): 629–639.spa
dc.relation.referencesVera M. Segmentación de estructuras cardiacas en imágenes de tomografía computarizada multi-corte. Ph.D. dissertation, Universidad de los Andes, Mérida-Venezuela, 2014spa
dc.relation.referencesVera M., Huérfano Y., Contreras J., Vera M. I., Salazar W., Vargas S., Chacón J. y Rodríguez J. (2017). Detección de hemorragia intracraneal intraparenquimatosa, en imágenes de tomografía computarizada cerebral, usando una técnica computacional no lineal. Latinoamericana de Hipertensión. 12(5), 125-130.spa
dc.relation.referencesMeijering H. Image enhancement in digital X–ray angiography. [Tesis Doctoral], Utrecht University, Netherlands, 2000spa
dc.relation.referencesGonzález R., Woods R. Digital Image Processing. USA: Prentice Hall, 2001spa
dc.relation.referencesPratt W. Digital Image Processing. USA: John Wiley & Sons Inc, 2007.spa
dc.relation.referencesNetravali A. y Haskell B. Digital Pictures: Representation, Compression, and Standards (2nd Ed), Plenum Press, New York, NY (1995).spa
dc.relation.referencesRabbani M. y Jones P. Digital Image Compression Techniques, Vol TT7, SPIE Optical Engineering Press, Bellvue, Washington (1991).spa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2spa
dc.rights.licenseAtribución-SinDerivadas 4.0 Internacional (CC BY-ND 4.0)spa
dc.rights.urihttps://creativecommons.org/licenses/by-nd/4.0/spa
dc.sourcehttps://www.researchgate.net/publication/329035614_Smoothing_filters_in_synthetic_cerebral_magnetic_resonance_images_A_comparative_studyspa
dc.subject.decsMagnetic Resonance
dc.subject.decsResonancia Magnética
dc.subject.decsRessonância Magnética
dc.subject.proposalSynthetic Cerebral images
dc.subject.proposalImágenes sintéticas cerebrales
dc.subject.proposalRician noise
dc.subject.proposalRuido Riciano
dc.subject.proposalGaussian filter
dc.subject.proposalFiltro Gausiano
dc.subject.proposalAnisotropic diffusion filter
dc.subject.proposalFiltro de difusión anisotrópica
dc.subject.proposalPSNR
dc.titleSmoothing filters in synthetic cerebral magnetic resonance images: A comparative study
dc.title.translatedFiltros suavizadores en imágenes sintéticas de resonancia magnética cerebral: un estudio comparativo
dc.typeArtículo de revistaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.coarversionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.type.contentTextspa
dc.type.driverinfo:eu-repo/semantics/articlespa
dc.type.redcolhttp://purl.org/redcol/resource_type/ARTspa
dc.type.versioninfo:eu-repo/semantics/publishedVersionspa
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Smoothing filters in synthetic cerebral magnetic resonance images_ A comparative study.pdf
Tamaño:
319.49 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
14.48 KB
Formato:
Item-specific license agreed upon to submission
Descripción: